Toshiba Magnia 3030 User Manual
Page 162
System Configuration Setup
Onboard SCSI Utility
144
Setting this item to “Enabled” makes the host adapter perform parity checks
to scan for normal data transfer through the SCSI bus.
Host Adapter SCSI Termination
: Enabled
Set whether the SCSI bus is to be terminated using the SCSI host adapter.
Do not change the setting.
Boot Device Options
Set the device for which the system is to be booted.
Boot Channel
: A First
Select the SCSI controller for which the system is to be booted. Do not
change the setting.
Boot SCSI ID
: 0
Select the SCSI ID of the device for which the system is to be booted. Do
not change the setting.
Boot LUN Number
: 0
Select the LUN of the device for which the system is to be booted. Do not
change the setting.
SCSI Device Confiugration
Set detailed configuration information for each SCSI device (SCSI ID).
Sync Transfer Rate (MB/Sec)
: 80.0
Set the maximum synchronous transfer rate of the onboard SCSI controller.
Initiate Wide Negotiation
: Yes
Setting to “Yes” specifies Wide SCSI whose data width is 16 bits.
Enable Disconnection
: Yes
Setting to “Yes” makes the adapter activate the disconnect/reconnect func-
tion for permitting multiple-command processing.
Send Start Unit Command
: Yes
Set whether a start unit command is to be sent from the adapter to start the
SCSI device.
Enable Write Back Cache
: N/C
Set whether the write-back cache is to be enabled or not.
BIOS Multiple LUN Support
: No
Set whether LUN is to be supported or not.