Pedestal model, Rack model – Toshiba Magnia 3030 User Manual
Page 22
Getting Started
Environmental considerations
4
- Ambient temperature:
50 to 95°F (10 to 35°C) (Pedestal model)
50 to 89°F (10 to 32°C) (Rack model)
- Ambient humidity: 30 to 80%Rh (No condensation)
NOTE: To avoid condensation when the room temperature is too high or too
low, wait about one hour after the room temperature has fallen within a range
of 50 to 95°F (10 to 35°C) before using the server.
Keep the server free from condensation during use and storage.
Pedestal model
Leave enough space around the server for Maintenance and ventilation.
Minimum clearances required for the installation of a pedestal model
Rack model
Installing a rack model requires special techniques and knowledge. So
instead of installing it yourself, ask an authorized Magnia service provider
for it. (A service fee is charged for.)
Use optional Toshiba rack and rack mount kit to install a rack model.
Leave a clearance of more than 24 inches (60 cm) before and behind the
rack to ensure well ventilation for the server.
Refer to “Magnia Series Rack Mount/Install Guide”.
8 inches (20 cm) or more
2 inches (5 cm) or more
12 inches (30 cm) or more
2 inches (5 cm) or more