beautypg.com

Setting up the server for operation – Toshiba Magnia 3030 User Manual

Page 195

background image

Emergency Management Port

Setting Up the Server for Operation

177

Setting Up the Server for Operation

Set up the server using the following procedure:

1 Start up the BIOS setup utility.

2 Make certain that “Enabled” is assigned to serial port 2 (COM2).

Select “Integrated Peripheral Configuration” from the Advanced Menu and
make certain that “Enabled” is assigned to “COM2”.

Enter EMP data.

3 Select the server menu. Next, select “System Management”.

Enter data in all necessary items when the following window is displayed

All settings in brackets above are defaults.

Option: “EMP Password Switch”

Enter the password required for server setup using the EMP function.
When “Disabled” is assigned in response to the starting prompt for user pass-
word entry, all users can access EMP just by clicking on the OK button.
When “Enabled” is assigned, the item “EMP Password” will be displayed;
enter your password.

Option: “EMP ESC Sequence”

Do not change the default.

Option: “EMP Hangup Line String”

Do not change the default.

>System Management:info

system Event Logging:

[Enabled]

Clear Event Log:

[No]

EMP Password Switch:

[Disabled]

EMP ESC Sequence: [+++]

EMP Hangup Line String: [ATH]

Modem Init String:

[AT&F0S0=1S14=0&D]

High Modem Init String: [0]

EMP Access Mode: [Disabled]

EMP Restricted Mode Access: [Disabled]

EMP Direct Connect/Modem Mode:[Direct Connect]