Emergency Management Port
Setting Up the Server for Operation
177
Setting Up the Server for Operation
Set up the server using the following procedure:
1 Start up the BIOS setup utility.
2 Make certain that “Enabled” is assigned to serial port 2 (COM2).
Select “Integrated Peripheral Configuration” from the Advanced Menu and
make certain that “Enabled” is assigned to “COM2”.
Enter EMP data.
3 Select the server menu. Next, select “System Management”.
Enter data in all necessary items when the following window is displayed
All settings in brackets above are defaults.
Option: “EMP Password Switch”
Enter the password required for server setup using the EMP function.
When “Disabled” is assigned in response to the starting prompt for user pass-
word entry, all users can access EMP just by clicking on the OK button.
When “Enabled” is assigned, the item “EMP Password” will be displayed;
enter your password.
Option: “EMP ESC Sequence”
Do not change the default.
Option: “EMP Hangup Line String”
Do not change the default.
>System Management:info
system Event Logging:
[Enabled]
Clear Event Log:
[No]
EMP Password Switch:
[Disabled]
EMP ESC Sequence: [+++]
EMP Hangup Line String: [ATH]
Modem Init String:
[AT&F0S0=1S14=0&D]
High Modem Init String: [0]
EMP Access Mode: [Disabled]
EMP Restricted Mode Access: [Disabled]
EMP Direct Connect/Modem Mode:[Direct Connect]