Sensor Data and LCD Setup Tool
The server has a variety of sensor-based fault-monitoring functions. In the fol-
lowing cases, settings must be modified using “Sensor Data and LCD Setup
Tool”:
Operating the system after removing redundant EPS-R units and cooling
fans
Deactivating the alarm buzzer activated by the occurrence of a power or
cooling fan fault
Setting the sleep switch to “Enabled” (or “Disabled”)
Changing the number of CPUs
To use “Sensor Data and LCD Setup Tool”, create a backup floppy disk from
“Toshiba Server Setup Tool”.
See “Making Floppy Disks” on page 43.
What you can set with “Sensor Data and LCD Setup Tool”
Operating the system after removing redundant EPS-R units
and cooling fans
The EPS-R cages and cooling fans of the server can take on a redundant config-
uration by having additional ones. Whether the EPS-R and cooling fans take on
a redundant configuration is monitored by the SMC board, and when redundant
EPS-R and cooling fans are removed, the SMC board will judge the server to
have entered into degenerate operation, and as a result, perform the following
functions:
Blinking the fault lamp (
)