Installing/removing an optional device – Toshiba Magnia 3030 User Manual
Page 74
Installing and Removing Hardware
Installing and Removing Optional Devices
56
Installing/removing an optional device
WARNING: When installing a peripheral unit, don’t open any part other than
those specified by the instructions.
If an unrelevant part is opened, it may cause an electric shock.
Install or remove an optional device following the procedure mentioned below.
1 Carefully read the precautions mentioned previously in this chapter (Before
starting operation) and check all the items.
2 Switch off all the peripheral units connected with the server.
3 If the server is running, shut it down and turn off the power.
4 Unplug the power cable of the server from the AC outlet or UPS (uninter-
ruptive power supply), and disconnect all cables from connectors on the
back of the server.
NOTE: Before starting the job, turn off the DC operate switch on the back of
the server (for the EPS-R model only) and disconnect the power cable from
the power supply. If an optional device is installed as the server is switched
on, it may cause failure of the server and the option.
5 Remove the covers from the server.
In case of the rack model, loosen the screws and pull the server out of the
rack before removing the panels.
6 Install or remove an optional device.
7 Make sure that there is neither tool nor dead part remaining inside the
server.
8 Attach the panels to the server.
In case of the rack model, fit the panels to the server before mounting it on
the rack and fasten the server to the rack with the screws.
9 Connect the peripheral units and switch them on.
10 Plug the server’s power cable connector into an AC outlet (or UPS) and then
switch on the server.
Some optional devices need setup with jumper switches and DIP switches.
See “SSU (System Setup Utility)” on page 105.