Verification test logs – HP StoreEver ESL G3 Tape Libraries User Manual

Page 178

background image

If the graphical report shows one or more marginal or failed results, inspect the picker. It should
rotate easily by hand, and the fingers should spring into a clamped position. Make sure both ro-
tation axis belts are free of debris. Also make sure that the storage is correctly seated in the I/E
station and that the I/E station and front door are completely shut.

If the problems persist, you may need to replace the picker assembly.

Verification Test Logs

Each verification test produces a test log that details all information and results from the individual
tests and sub-tests. In addition, the log includes information to help you understand the test results and
to help resolve any problems encountered.

To view a test log:

1.

Click Reports on the Verification Tests dialog box to display the report window.

2.

Select the test to view in the Test Results region of the dialog box. You can view results for the
five most recent tests.

3.

Click Reports.
This log file is appended with data as each test finishes. You can repeat the test if any problems
are found and fixed. If the Verification Tests dialog box was not closed during the retesting, all
results are contained in one log file.

4.

Click the Text tab.

5.

To save the information that the test generates, click Send.
If you are using the remote LMC client, you can choose to save the log to your hard drive. If you
choose to save directly to your hard drive, the report listing and test log are combined into one
text file.

A test log provides the following information:

The test output is from the library alignment test.

The test title is always shown between rows of equal signs.

A brief guide for understanding coordinates and offsets used in the test results is provided near
the beginning of the log.

The X-axis and Y-axis limits applied by this test are shown. MARGINAL output is placed between
parentheses, and FAILED output is placed between brackets; for example, (30) and [45].

The results of the sub-test appear between dashed lines.

Coordinates are represented as A (aisle), F (frame), R (rack), S (section), C (column), and R (row).

All location values are in 0.1 mm.

All results that you should review are identified with four arrows (>>>>) in the column to the left
of the detailed results.

At the end of every test, summary results of every sub-test are given. The overall test result appears
between asterisk lines, and a summary of sub-test results follows.

Figure 22

shows an example of a test log.

Maintaining the library