background image

Figure 14

shows the section, column and row numbering for rack 1 of a library that contains LTO

cartridges. See

Figure 15

to review rack numbering.

2. Row (individual slot)

1. Column

4. Section

3. X-axis rail counts as section 6

Figure 15 Section, Column, and Row Numbering for Rack 1 - LTO Cartridges

.

NOTE:

Tape drives that are installed in rack 1 of a control module or an expansion module replace storage
in columns 1 and 2. Because drives are installed from the bottom to the top, you lose the storage
starting in section 10 first. You do not lose the magazine in columns 1 and 2 of section 5.
Column 1 never contains storage in the control module.

Figure 16

shows the section, column, and row numbering for rack 2 of a library that contains LTO

cartridges. This is shown as you face the inside of the opened module door.

NOTE:

The cartridges in the 24-slot LTO I/E station are addressed as part of column 3 and are in sections
1 through 4 (top to bottom). When you have an I/E station installed on rack 2, there are no cartridges
in columns 3 and 4 of section 5. See

Figure 16

.

HP Enterprise Systems Library (ESL) G3 Tape Library

103