beautypg.com

Network settings measure mode settings – Spectra Precision Survey Pro v5.0 User Manual

Page 32

background image

Note: This setting is only available when your receiver model is Hiper .

Network Settings

[Job] [Settings] [Networks Card]

To add a new network to the list, tap the add network icon

in the Networks tab.

Name: Enter a unique name for the network server.

Address: Enter the IP address for the network server.

Port: Enter the IP port for the network server.

[Save]: Tap to save the network.

To rename a network, tap the gear icon

and change the Address and Port if required.

Measure Mode Settings

[Job] [Settings] [Measure Mode]

The Measure Mode card is used to configure the RTK data collection settings.

Accept Solution Quality: Control the solution quality acceptable for storing measurements. You have two options:

Fixed RTK only: Allows storage of fixed solution only.
Code, Float, or Fix: Allows storage of any differential solution.

Use Acceptance Criteria: Select to apply criteria to measurement acceptance. When checked, only measurements
with RMS and/or PDOP values below the threshold will be accepted. To use less than all three criteria, check this box
but enter 0.0 for the criteria you do not wish to apply.

H RMS: Horizontal RMS threshold for automatic acceptance or warning on point acceptance.
V RMS: Vertical RMS threshold for automatic acceptance or warning on point acceptance.
PDOP: PDOP threshold for automatic acceptance or warning on point acceptance.

Automatically Accept Data Collection: Select to automatically accept data collection points when the criteria is met.
When checked, both the data and Offset Shots screens will automatically accept points once the measurement is better
than the specified criteria. Data collection routines will always collect at least 5 seconds worth of data before
automatically accepting points based on criteria.

Epoch Averaging: Set a number of epochs to average in the software. If this number is greater than one, the software
will use the number of epochs specified to calculate the final position using a simple (non weighted) average.

Note: This function is not appropriate for every receiver. Some receivers, when dynamics are set to ‘static’, use
Kalman filtering and other superior techniques to calculate an average position. In this case, the position returned
from the receiver is better with each epoch and you may degrade your result by averaging with the software. You
should check with your receiver manufacturer for specific recommendations on field procedure.

Survey Pro Help 5.00

32