Instrument settings - screen 2 – Spectra Precision Survey Pro v5.0 User Manual

Page 23

background image

Note: When running in leveling mode, the [Instrument Settings…] can be selected for Manual Mode to open the

Level Method

screen.

[Instrument Settings]: Opens the next

Instrument Settings

screen where the settings in the selected instrument profile

can be modified.

Note: When editing an existing instrument profile, you cannot modify the instrument brand or model.

[Create New Instrument]: Opens the next

Instrument Settings

screen where you can configure the settings for a new

instrument and create a new instrument profile.

[Activate]: Activates the selected instrument profile.

[GeoLock]: Opens the

GeoLock Settings

screen.

[Delete]: Deletes the selected instrument profile.

[Import]: Imports an instrument profile from an instrument profile file that was previously loaded on the data
collector.

[Export]: Saves the selected instrument profile to a file, which can then be transferred to another data collector and
then imported.

Instrument Settings – Screen Two

The second Instrument Settings screen opens whenever a new instrument profile is being created, or when an existing
profile is being edited.

The options available on this screen will vary slightly depending on the total station model selected.

Name: The name of the instrument profile being created or changed. This is the name that appears in the list on the
first

Instrument Settings

screen.

Brand: Specify the manufacturer of the instrument that you are using from a dropdown list.

Model: Specify the model of the instrument that you are using from a dropdown list.

Serial Port: The serial port on the data collector used for communications with the total station. (Bluetooth can also be
selected on a Recon or Ranger 500X for wireless communication between the data collector and a compatible total
station.)

Baud Rate: The speed at which communication occurs with the total station. This must match the baud rate
configured within the total station.

Parity: The parity used for communication with the instrument. This must match the parity setting configured within
the total station.

PIN: (applicable only when using Bluetooth with a Recon or Ranger 500X and a supported total station) The Personal
Identification Number that was entered in the total station. These numbers must match for successful communications.

[Bluetooth…] (applicable only when using Bluetooth with a Recon or Ranger 500X and a supported total station):

Survey Pro Help 5.00