NETGEAR MS510TXPP 8 Port Gigabit PoE Managed Switch User Manual
Page 75
Smart Managed Pro Switches MS510TX and MS510TXPP
Configure System Information
User Manual
75
6.
To view additional information about the remote device, click the hyperlink in the MSAP
Entry column.
A pop-up window displays information for the selected port.
The following table describes the information transmitted by the neighbor.
Port ID
The physical address of the port on the remote system from which the data
was sent.
System Name
The system name associated with the remote device. If the field is blank, the
name might not be configured on the remote system.
Field
Description
Port Details
Local Port
The interface on the local system that received LLDP information from a
remote system.
MSAP Entry
The Media Service Access Point (MSAP) entry number for the remote device.
Basic Details
Chassis ID Subtype
The type of data displayed in the Chassis ID field on the remote system.
Chassis ID
The remote 802 LAN device’s chassis.
Port ID Subtype
The type of data displayed in the remote system’s Port ID field.
Port ID
The physical address of the port on the remote system from which the data
was sent.
Port Description
The user-defined description of the port.
System Name
The system name associated with the remote device.
System Description
The description of the selected port associated with the remote system.
System Capabilities
The system capabilities of the remote system.
Managed Addresses
Address SubType
The type of the management address.
Address
The advertised management address of the remote system.
Interface SubType
The port subtype.
Interface Number
The port on the remote device that sent the information.
Field