NETGEAR MS510TXPP 8 Port Gigabit PoE Managed Switch User Manual
Page 306
Smart Managed Pro Switches MS510TX and MS510TXPP
Monitor the System
User Manual
306
Critical, Alert, and Emergency. The default severity level is Alert. The severity can be one
of the following levels:
•
Emergency
. The highest warning level. If the device is down, or not functioning
properly, an emergency log message is saved to the device.
•
Alert
. The second-highest warning level. An alert log message is saved if a serious
device malfunction occurs, such as all device features being down. Action must be
taken immediately.
•
Critical
. The third-highest warning level. A critical log message is saved if a critical
device malfunction occurs, for example, two device ports are not functioning, while
the rest of the device ports remain functional.
•
Error
. A device error occurred, such as a port being offline.
•
Warning
. The lowest level of a device warning.
•
Notice
. Normal but significant conditions. Provides the network administrators with
device information.
•
Informational
. Provides device information.
•
Debug
. Provides detailed information about the device.
8.
Click the
Apply
button.
Your settings are saved.
The Total Number of Messages field shows the total number of persistent log messages
that are stored on the switch. The 128 most recent entries are displayed on the page.
The FLASH Logs table displays the log messages, if any.
The following table describes the nonconfigurable information displayed on the page.
Table 71. FLASH Logs table information
Field
Description
Log Index
An index number for the log message.
Log Time
The time that the message was logged.
Description
The description of the message.