In the
Size
field, enter the size of the probe packets.
The range is 64 to 1472. The default value is 64.
14.
Click the
Apply
button.
A traceroute request is sent to the specified IPv4 address or host name. The results are
displayed below the configurable data in the Results field.
If a reply to the traceroute is received, a message similar to the following one is displayed:
1 10.5.225.33 20 ms 10 ms 30 ms
2 10.5.225.225 10 ms 10 ms 10 ms
3 192.254.254.3 10 ms 30 ms 20 ms
Hop Count = 3 Test attempt = 9 Test Success = 3
Send an IPv6 Traceroute
Use this page to tell the switch to send a traceroute request to a specified IPv6 address or
host name. You can use this to discover the paths that packets take to a remote destination.
Once you click the
Apply
button, the switch sends a traceroute and the results are displayed
below the configurable data.
To send an IPv6 traceroute:
1.
Connect your computer to the same network as the switch.
You can use a WiFi or wired connection to connect your computer to the network, or
connect directly to a switch that is off-network using an Ethernet cable.
2.
Launch a web browser.
3.
In the address field of your web browser, enter the IP address of the switch.
If you do not know the IP address of the switch, see
The login window opens.
4.
Enter the switch’s password in the
Password
field.
The default password is
password
.
The System Information page displays.
5.
Select
Maintenance > Troubleshooting > Traceroute IPv6
.
The Traceroute IPv6 page displays.
6.
In the
IPv6 Address/Host Name
field, enter the IPv6 address or host name of the device for
which the path must be discovered.
7.
In the
Probes Per Hop
field, enter the number of probes per hop.
The range is 1 to 10. The default value is 3.
8.
In the
Max TTL
field, enter the maximum time to live (TTL) for the destination.
The range is 1 to 255. The default value is 30.