Table 6.49 – Avago Technologies LSI53C876E User Manual
Page 291
AC Characteristics
6-59
Table 6.48
SCSI-2 Fast Transfers (10.0 Mbytes/s (8-Bit Transfers) or 20.0 Mbytes/s
(16-Bit Transfers), 40 MHz Clock
Symbol
Parameter
Min
Max
Unit
t
1
Send SREQ/ or SACK/ assertion pulse width
35
–
ns
t
2
Send SREQ/ or SACK/ deassertion pulse width
35
–
ns
t
1
Receive SREQ/ or SACK/ assertion pulse width
20
–
ns
t
2
Receive SREQ/ or SACK/ deassertion pulse width
20
–
ns
t
3
Send data setup to SREQ/ or SACK/ asserted
33
–
ns
t
4
Send data hold from SREQ/ or SACK/ asserted
45
–
ns
t
5
Receive data setup to SREQ/ or SACK/ asserted
0
–
ns
t
6
Receive data hold from SREQ/ or SACK/ asserted
10
–
ns
Table 6.49
SCSI-2 Fast-20 SE Transfers (20.0 Mbytes/s (8-Bit Transfers) or
40.0 Mbytes/s (16-Bit Transfers), 80 MHz Clock) with Clock Doubled
Internally
Symbol
Parameter
Min
Max
Unit
t
1
Send SREQ/ or SACK/ assertion pulse width
16
–
ns
t
2
Send SREQ/ or SACK/ deassertion pulse width
16
–
ns
t
1
Receive SREQ/ or SACK/ assertion pulse width
10
–
ns
t
2
Receive SREQ/ or SACK/ deassertion pulse width
10
–
ns
t
3
Send data setup to SREQ/ or SACK/ asserted
12
–
ns
t
4
Send data hold from SREQ/ or SACK/ asserted
17
–
ns
t
5
Receive data setup to SREQ/ or SACK/ asserted
0
–
ns
t
6
Receive data hold from SREQ/ or SACK/ asserted
6
–
ns