I/O Instruction

5-21

R

Reserved

[23:20]

ENDID[3:0]

Encoded SCSI Destination ID

[19:16]

This 4-bit field specifies the destination SCSI ID for an I/O
instruction.

R

Reserved

[15:11]

CC

Set/Clear Carry

10

This bit is used in conjunction with a Set or Clear
instruction to set or clear the Carry bit. Setting this bit
with a Set instruction asserts the Carry bit in the ALU.
Setting this bit with a Clear instruction deasserts the
Carry bit in the ALU.

TM

Set/Clear Target Mode

9

This bit is used in conjunction with a Set or Clear
instruction to set or clear Target mode. Setting this bit
with a Set instruction configures the LSI53C876 as a
Target device (this sets bit 0 of the

SCSI Control Zero

(SCNTL0)

register). Clearing this bit with a Clear

instruction configures the LSI53C876 as an Initiator
device (this clears bit 0 of the SCNTL0 register).

R

Reserved

[8:7]

ACK

Set/Clear SACK/

6

R

Reserved

[5:4]

ATN

Set/Clear SATN/

3

These two bits are used in conjunction with a Set or Clear
instruction to assert or deassert the corresponding SCSI
control signal. Bit 6 controls the SCSI SACK/ signal. Bit 3
controls the SCSI SATN/ signal.

Setting either of these bits sets or resets the
corresponding bit in the

SCSI Output Control Latch

(SOCL)

register, depending on the instruction used. The

Set instruction is used to assert SACK/ and/or SATN/ on
the SCSI bus. The Clear instruction is used to deassert
SACK/ and/or SATN/ on the SCSI bus.

Since SACK/ and SATN/ are Initiator signals, they are not
asserted on the SCSI bus unless the LSI53C876 is
operating as an Initiator or the SCSI Loopback Enable bit
is set in the

SCSI Test Two (STEST2)

register.