92
Rockwell Automation Publication PFLEX-IN029B-EN-P - August 2014
Chapter 3
PowerFlex 700H and 700S Drives - Frame 11 Procedures
Move the Control Frame and Remove the Air Flow Plate and
Protective Covers
You must move the control frame and remove the air flow plate and protective
covers from the drive in order to access fan system components on the drive
power structure. Follow these steps to move the control frame and remove the air
flow plate and protective covers.
1.
Review the General Precautions on page
2.
Remove power from the drive. See Remove Power from the Drive on page
.
3.
If moving the control frame from a DC input drive with pre-charge
interlock, disconnect the wiring from terminal strip X50.
4.
Loosen the two hexalobular screws that secure the control frame to the
enclosure and swing the control frame away from the drive.
T20
3.0 N
•
m (27 lb
•
in)
4
3