beautypg.com

Rockwell Automation 20Y PowerFlex 700H, 700S, and 700AFE Drive Fan Systems, Frames 9...14 User Manual

Page 43

background image

Rockwell Automation Publication PFLEX-IN029B-EN-P - August 2014

43

PowerFlex 700H and 700S Drives - Frame 9 Procedures

Chapter 1

21.

Secure the fan inverter cover to the drive using the M4 x 8 mm
POZIDRIV screw.

22.

Install the lower protective cover in the reverse order of removal. See
Remove the Lower Protective Cover on page

24

.

23.

Remove the backing from the drive modification label and attach the label,
in a clearly visible location, to the front of the drive.

24.

Write “DC fan retrofit” and the installation date on the label.

Main AC Fan (20-PP01080) and Main DC Fan (SK-Y1-DCFAN1) Assembly
Removal and Installation

Follow these steps to measure the resistance between the main fan supply wires
and remove and replace the main fan, if necessary.

Notes:

To identify which fan is installed in your drive, see Fan Inverter System
Block Diagrams
on page

257

.

For AC fan systems, the sheet metal bracket is available as a spare part (SK-
H1-FR9BRKT). See page

288

for details. For DC fan systems, the sheet

metal bracket is only available as part of the retrofit kit (SK-H1-
DCFANRETROFIT-F9). See page

289

for details.

The main fan replacement kit only contains the fan motor and impeller
assembly. Therefore, if the sheet metal mounting bracket is not available as
a spare part for your fan system, it must be reused.

1

2

3

4

ON

X6

X1

X4

X5

X7

S1

X2

X8

PZ2
1.3 N

m (11.5 lb

in)

Series A Cover Shown