PowerFlex 700H and 700S Drives - Frame 14
Procedures

This chapter contains spare part information and procedures for testing and
replacing fan system components for frame 14 PowerFlex 700H and PowerFlex
700S drives. See Appendix A PowerFlex 700H and 700S Diagnostic Procedures
on page

255

for additional component test procedures.

Frame 14 Drive
Configurations

For frame 14 drives, there are different configurations based on the power rating.
For drives with less than 1500A, there are 3 converter sections and 6 inverter
sections. For drives greater than 1500A, there are 4 converter sections and 6
inverter sections.

Frame 14 Fan System Spare
Parts

Frame 14 PowerFlex 700H and PowerFlex 700S drives are essentially two parallel
frame13 drives. Therefore, the spare parts are identical to the frame 13, with the
exception that there are twice as many parts required. The procedures for
replacing frame 14 fan system components are also the same as those for frame 13
drives.

See Frame 13 Fan System Replacement Procedures on page

134

for detailed

replacement procedures. See Frame 14 System Diagrams on page

182

for more

information.

Topic

Page

Frame 14 Drive Configurations

179

Frame 14 Fan System Spare Parts

179

Frame 14 System Diagrams

182

Frame 14 1500A Drive

Frame 14 Drive Above 1500A

Converter

Inverter

Inverter

Converter

Inverter

Inverter

Converter