Inverter units o – Rockwell Automation 20Y PowerFlex 700H, 700S, and 700AFE Drive Fan Systems, Frames 9...14 User Manual
Page 157
![background image](/manuals/581734/157/background.png)
Rockwell Automation Publication PFLEX-IN029B-EN-P - August 2014
157
PowerFlex 700H and 700S Drives - Frame 13 Procedures
Chapter 5
Inverter Units
1.
Review the General Precautions on page
2.
Remove power from the drive. See Remove Power from the Drive on page
3.
Move the control frame, and remove the screens, airflow plates, and
protective covers. See Move the Control Frame, and Remove the Screens,
Airflow Plates, and Protective Covers on page
4.
Remove the main fan assemblies. See Remove the Main Fan Assembly on
page
.
5.
Remove the AC fan inverter assemblies. See Removing the Main AC or
DC Fan Power Supply Assemblies (Inverter Only) on page
6.
For AC input standalone drives only, remove the wire harness that
connects the fans on the converter and inverter units.
Note: DC input drives do not have an converter section, so there is no
converter to inverter interconnect wire harness.
6
Converter Section
Inverter Section