Rockwell Automation 20Y PowerFlex 700H, 700S, and 700AFE Drive Fan Systems, Frames 9...14 User Manual
Page 168
168
Rockwell Automation Publication PFLEX-IN029B-EN-P - August 2014
Chapter 5
PowerFlex 700H and 700S Drives - Frame 13 Procedures
23.
Connect the wire harness supplied in the retrofit kit that connects the fans
on the converter and inverter units.
24.
Connect the additional DC– wire on the new fan wire harness supplied in
the retrofit kit to the DC– terminal on the inverter fuse base and secure
the wire using two tie wraps.
25.
Remove the backing from the drive modification label and attach the label
to the front of a main fan housing.
26.
Write “DC fan retrofit” and the installation date on the label.
23
Converter Section
Inverter Section
24
24
24
Note: Converter section shown
This manual is related to the following products: