9.
Connect the fan power supply wires to the bottom of the fuse holders.
Note that the red wire (+DC) is connected to the left side terminal and
the black wire (-DC) is connected to the right side terminals.
10.
Install the new main DC fans in the fan housings using the M5 x 10 mm
POZIDRIV screws supplied in the kit. Final torque is 3.5 N
•
m (31.0
lb
•
in). See Remove the Main Fan Assembly on page
for details.
11.
Remove the backing from the drive modification label and attach the label
to the front of a main fan housing.
12.
Write “DC fan retrofit” and the installation date on the label.
9