beautypg.com

Rockwell Automation 20Y PowerFlex 700H, 700S, and 700AFE Drive Fan Systems, Frames 9...14 User Manual

Page 63

background image

Rockwell Automation Publication PFLEX-IN029B-EN-P - August 2014

63

PowerFlex 700H and 700S Drives - Frame 10 Procedures

Chapter 2

Remove the Main AC or DC Fan Power Supply Assemblies

You must remove the main fan power supply assemblies from the drive in order to
replace the AC or DC fan power supply circuit board, AC fan inverter output
transformer, and AC fan inverter capacitor. Follow these steps to remove the
main fan power supply assemblies.

Note: If you are replacing only one fan power supply assembly, only complete the
steps for the side of the drive that contains that assembly. When replacing a failed
AC fan system with a DC fan system, remove and replace both AC fan systems.

1.

Review the General Precautions on page

17

.

2.

Remove power from the drive. See Remove Power from the Drive on page

59

.

3.

Move the control frame and remove the air flow plate and protective
covers from the drive. See Move the Control Frame and Remove the Air
Flow Plate and Protective Covers on
page

60

.

4.

Remove the cable ties that secure the power cables with brown/orange
insulation. Note: This will allow you to move the power cables while
removing the fan inverter assemblies.

Left-side fan assembly

Right-side fan assembly

4

4

Note: AC fan systems shown