beautypg.com

Rockwell Automation 20Y PowerFlex 700H, 700S, and 700AFE Drive Fan Systems, Frames 9...14 User Manual

Page 215

background image

Rockwell Automation Publication PFLEX-IN029B-EN-P - August 2014

215

PowerFlex 700AFE Drive - Frame 10 Procedures

Chapter 7

4.

Remove the protective cover in the LCL Filter cabinet.

LCL Filter DC Fan Fuses (20-PP20202) Removal and Installation

See

Figure 20

on page

186

for the location of the LCL filter DC fan fuses.

1.

Review the General Precautions on page

17

.

2.

Remove power from the AFE. See Remove Power from the AFE on page

192

.

3.

Install the LCL filter DC fan fuses in the reverse order of removal.

LCL Filter Fan DC Power Supply (SK-Y1-DCPS1-D460 or SK-Y1-DCPS1-F325) Removal and
Installation

Note: It is not necessary to remove the fan assembly from the LCL filter, but by
doing so, it may be easier to replace the fan DC power supply circuit board.

The LCL filter fan DC power supply wiring diagram is shown in

Figure 25

. The

diagram shows the connections to the AFE power structure and DC bus.

Protective Cover

IP21 (Rittal) cabinet
shown with doors
removed

LCL Filter Fan and DC

Power Supply (behind

cover)