Rockwell Automation 20Y PowerFlex 700H, 700S, and 700AFE Drive Fan Systems, Frames 9...14 User Manual
Page 175
Rockwell Automation Publication PFLEX-IN029B-EN-P - August 2014
175
PowerFlex 700H and 700S Drives - Frame 13 Procedures
Chapter 5
AC Fan
: If the measurements are not similar to those in this table, replace
the AC fan.
DC Fan
: If the measurements are not similar to those in this table, replace
the DC fan.
6.
For AC fan systems, install the new fan assembly in the reverse order of
removal. For DC fan systems, complete the remaining steps.
Connection wires
Resistance ±5%
Black-Brown
62
Ω
Brown-Blue
36
Ω
Blue-Black
27
Ω
Green-chassis
0
Ω
Connection wires
Resistance ±5%
Red-Blue
∞ Ω
Red-White
∞ Ω
White-Yellow
∞ Ω
Blue-White
∞ Ω
Blue (Motor) Pin 4
Green/Yellow (Ground) Pin 1
Brown (Motor) Pin 3
Black (Motor) Pin 2
AC Fan Pinouts
White (Tach Output) Pin 3
Red (+) Pin 1
Blue (-) Pin 4
Yellow (Control Output) Pin 2
DC Fan Pinouts