Rockwell Automation 20Y PowerFlex 700H, 700S, and 700AFE Drive Fan Systems, Frames 9...14 User Manual
Page 108
![background image](/manuals/581734/108/background.png)
108
Rockwell Automation Publication PFLEX-IN029B-EN-P - August 2014
Chapter 3
PowerFlex 700H and 700S Drives - Frame 11 Procedures
9.
If the original, defective capacitor being replaced is series B, continue with
the next step. If the original, defective capacitor being replaced is series A,
secure the new fan capacitor adapter bracket to the AC fan inverter
assembly using the new M8 x 16 mm hexagonal socket screw and washer
provided in the replacement kit.
10.
For the V phase AC fan inverter assembly, the fuse holder and bracket to
which it is secured must be installed on top of the new adapter bracket.
Phase U and W Fan Inverter Assemblies
Phase V Fan Inverter Assembly
New Adapter Bracket
New Adapter Bracket
Existing Bracket (and Fuse
Holder - Not Shown)
8 mm
12 N
•
m (106 lb
•
in)
Note: AC Fan System Shown
10