PowerFlex 700H and 700S Drives - Frame 11 Procedures
Chapter 3
5.
Cut the cable ties securing the wires marked Brown and Blue.
6.
Disconnect the AC fan capacitor wire connectors marked Brown and
Blue.
7.
If a series A capacitor is installed, continue with the next step. If a series B
capacitor is installed, measure the value of the capacitor. If the value of the
capacitor is not 7
μF, continue with the next step.
8.
Unscrew and remove the fan capacitor from the AC fan inverter assembly.
6
5
8
Series B Capacitor in a Right-side
AC Fan Inverter Assembly Shown.
Series A Capacitor in a Right-side
AC Fan Inverter Assembly Shown
Series A Capacitor Shown
Note: AC Fan System Shown