beautypg.com

Hydraulic system – SkyTrak 8042 Service Manual User Manual

Page 460

background image

8.45

Model 8042, 10042, 10054 Legacy

Rev. 10/03

Hydraulic System

Not

OK

NOTE:

When checking pressures in
circuits, refer to Section 8.7,
“Hydraulic System Testing,” f
or
correct pressure readings.

Before troubleshooting any
hydraulic circuit, ALWAYS
begin by checking the
following:

1. Hydraulic oil level in the

reservoir

2. All hoses, tubes, fittings

for leaks, kinks,
interference, etc.

3. Air in the lines

Not

OK

Not

OK

If the outriggers do not go

down, check the left and

right outrigger switches.

Check pump flow.

Not

OK

Check outrigger shuttle valve

on main control valve.

Replace shuttle valve.

If OK

Repair/replace pump.

Refer to Section 9.14.5,

“Outrigger Switches (10042/

10054 Only).”

Check the left and right

outrigger cylinders for

packing leaks.

If OK

Not

OK

Check the solenoid valves on

the outrigger valve.

Refer to Section 9.7.42, “10042

Outrigger Circuit and

Troubleshooting,” and Section

9.7.43, “10054 Outrigger Circuit

and Troubleshooting.”

If OK

Not

OK

Not

OK

Replace solenoid valves.

Replace pilot-operated

check valve(s).

If OK

Check the pilot-operated check

valve in each outrigger cylinder.

Check the spools in the

solenoid valves.

If OK

Repair/replace outrigger

cylinder(s).

If OK

NOTE:

Refer to Section 2.5.4,
“Performance Specifications,”

for

approximate cylinder cycle
times. The operation of the
system function should
approximate the times listed.

This manual is related to the following products: