Hydraulic system – SkyTrak 8042 Service Manual User Manual
Page 458

8.43
Model 8042, 10042, 10054 Legacy
Rev. 10/03
Hydraulic System
Not
OK
Not
OK
If the outriggers do not go
up, check the left and right
outrigger switches.
Check pump flow.
Not
OK
Check outrigger shuttle valve
on main control valve.
If OK
Not
OK
Check the left and right
outrigger cylinders for
packing leaks.
If OK
Not
OK
Check the solenoid valves on
the outrigger valve.
If OK
Not
OK
Not
OK
If OK
Check the counterbalance valve
in each outrigger cylinder.
Check the spools in the
solenoid valves.
If OK
If OK
NOTE:
When checking pressures in
circuits, refer to Section 8.7,
“Hydraulic System Testing,” for
correct pressure readings.
Before troubleshooting any
hydraulic circuit, ALWAYS
begin by checking the
following:
1. Hydraulic oil level in the
reservoir
2. All hoses, tubes, fittings
for leaks, kinks,
interference, etc.
3. Air in the lines
NOTE:
Refer to Section 2.5.4,
“Performance Specifications,” for
approximate cylinder cycle
times. The operation of the
system function should
approximate the times listed.
Replace shuttle valve.
Repair/replace pump.
Refer to Section 9.14.5,
Replace solenoid valves.
Replace counterbalance valve(s).
Repair/replace outrigger
cylinder(s).
Refer to Section 9.7.42, “10042