Triton Isis User Manual
Page 99
June 2004 Isis® Sonar User's Manual, Volume1
85
5. Press
[Shift] [ONLINE] again to put the plotter on-line.
To configure Isis for the 195 or 200 plotter
1. Run Isis and start playing back a file. Press
the playback.
2. Choose the printer icon on the toolbar at the top of the Isis
window.
3. Choose
Waverley 195 as the printer.
4. Choose
Plot All to print all channels across the page.
5. Verify
that
Fast Output is not checked.
6. Set Status to On.
7. Choose
OK.
8. Press SPACEBAR to resume playback.
Note:
If you finish using the plotter and then turn it off, Isis might
not be able to “see” the Sentinel attached to the system,
and Isis may stop running (or even be unable to start). The
solution is to turn the plotter back on or disconnect it.
To print (plot) the current Isis imagery with the 195 or 200
plotter
1. Reset your plotter to clear out any extraneous characters that
might still be in your plotter’s buffer.
2. Choose
Plot Screen Now or click OK.
Note:
If you have enabled Bottom Track (first return) from
View→Overlay of the main menu, your bottom tracking lines will
appear in your hardcopy.
If your imagery didn’t print after you clicked Plot Screen Now, you
may need to do some additional testing.
To test for general printing capability
• Run the test program that comes with your
Waverley/Dowty/Ultra 195 or 200 plotter.
Chapter 5: Printing in Isis