Triton Isis User Manual
Page 239

June 2004 Isis® Sonar User's Manual, Volume1
225
2. Select or deselect the options you want and click OK.
Table 9-10 describes the options found in the dialog box. Subgroups of the
dialog box are shown in bold face headings that span all columns.
Table 9-10. Output Options in Subbottom Picking and Tracking
Function Name Possible Actions
Effect of Actions Taken
Store points based on (all choices can be inclusive)
Event Number
Check or uncheck the box. Isis records the subbottom data
occurring at the event number.
Points can be stored based on
changing event numbers.
Time
Check or uncheck the box. Isis records subbottom data
occurring at the specified time
interval.
Distance Once
every ___ meters
Check or uncheck the box
and specify the distance.
Isis records subbottom data
occurring at the specified distance
interval. This is the default case,
with 10 meters being the default
interval.
Note:
Isis records subbottom data occurring at the specified distance interval.
This is the default case, with 10 meters being the default interval.
If you disable all three possible ways to store the
points of your reflectors, any Output File referenced
in the Subbottom Picking and Tracking dialog box will
be empty when you choose Flush All at the end of
your subbottom picking and tracking session. To
avoid this problem, choose at least one type of point
to store.
Chapter 9: Using the Tools Menu