beautypg.com

5 interpreting the sbp log file – Triton Isis User Manual

Page 241

background image

June 2004 Isis® Sonar User's Manual, Volume1

227

Distance in
Meters (m)

Check or
uncheck the box.

Distance in meters (distance from sensor to
reflector)

Distance in
Milliseconds
(ms)

Check or
uncheck the box.

Distance in Milliseconds (from sensor to
reflector)

Space between columns

Space between
columns

Type a number
in the box.

This specifies how many characters to assign
to each reflector’s column in the output file.

Include altitude sensor depth in distance

Include altitude
sensor depth in
distance

Check or
uncheck the box.

The distance (in meters) or time (in
milliseconds) from the surface to the sensor is
added to Distance in meters and Distance in
Milliseconds options found in the For each
reflector include
subgroup.



To turn off a reflector

1. Move the cursor to the right side of a tracked reflector.
2. Hold down the button and click the right trackball button.
3. This right-click action anchors the tracking line and determines

the right-side end of the reflector.

9.14.5 Interpreting the SBP Log File

A typical ASCII file generated by Isis while tracking reflected subbottom
layers is shown in Figure 9-29.

Chapter 9: Using the Tools Menu