From application server to densité, From densité to application server, To/from application server to/from snmp devices – Grass Valley iControl V.6.02 User Manual
Page 89: From application servers to ir controller, From application server to/from ntp server

iControl
User Guide
79
From Application Server to Densité
From Densité to Application Server
To/from Application Server to/from SNMP Devices
From Application Servers to IR Controller
From Application Server to/from NTP Server
Service
Port
Transport
Notes
Densité
5100,
5110
TCP
Required if Densité controller is installed. Recommendation is to
isolate Densité on ETH1 for optimal performance. Can also be
installed remotely to communicate with Application Server over
WAN.
Service
Port
Transport
Notes
None
Response is sent through the connection initiated by the
Application Server.
Service
Port
Transport
Notes
SNMP
161,
162
UDP
Simple Network Management Protocol, used for
communications between iControl and third party devices.
Required for Application Server acting as an agent or a manager.
SNMP Health
Monitoring
Agent
1161
UDP
Required for centralized Application Server Health Monitoring
Service
Port
Transport
Notes
IR Controller
4998
TCP, UDP
Used for set-top box control via infrared signal
Service
Port
Transport
Notes
NTP
123
UDP
Used for Network Time Protocol synchronization, which is
strongly recommended in a multiple Application Server
configuration. Port needs to be open in both directions.