Configuring the icontrol services gateway – Grass Valley iControl V.6.02 User Manual
Page 68

Getting Started with iControl
Deleting an Alarm Publication Lookup Location Entry
58
3. Restart the specific service (e.g. Densité Manager) that you wish to publish to the remote
GSM, or restart iControl to publish all services to the remote GSM (see
Deleting an Alarm Publication Lookup Location Entry
To delete an Alarm publication lookup location entry
1. On the iControl—Lookup location page, in the Alarm publication lookup table, find the
IP address corresponding to the Application Server whose entry you would like to delete.
2. In this row, click Delete.
The specified IP address is removed from the Alarm publication lookup table.
Configuring the iControl Services Gateway
The iControl Services Gateway is software that enables external devices to access resources
(via XML) on an iControl network. You should activate the iControl Services Gateway on an
Application Server if any of the following situations apply:
• an RCP-100 or RCP-200 remote control unit is being used as a client on the Application
Server
• the Line Selection function of the Line Scope option for the VCP and SCP series of video
probes is being used in iC Web
REQUIREMENT
Before beginning this procedure, make sure you have opened the iControl—Lookup location
page on the Application Server hosting the Densité or ImageStore services you no longer
wish to be visible outside the subnet (see