VF / DSL Cable Qualifier

48

return to the Main Menu.



Time:

To change the Time setting, use the Arrow Keys to move the cursor so that the current
Time value is highlighted. Use the Alphanumeric Keypad to enter the desired value.
The format is hhmmss meaning 2 digit hour (24 hour clock) followed by the 2 digit
minute and then followed by seconds (2 digits). Press ENTER when the value is
correctly entered to save your changes. More parameters can be changed at this
point, or press MAIN MENU to return to the Main Menu.

Baud Rate:

To change the Baud Rate setting, use the Arrow Keys to move the cursor so that the
current Baud Rate value is highlighted. Available options are 300, 1200, 2400, 9600,
19200, 38400, 57600, and 115200. Press ENTER when the value is correctly selected
to save your changes. More parameters can be changed at this point, or press MAIN
MENU

to return to the Main Menu.

Parity:

To change the Parity setting, use the Arrow Keys to move the cursor so that the
current Parity value is highlighted. Available options are None, Even, and Odd. Press
ENTER

when the value is correctly selected to save your changes. More parameters

can be changed at this point, or press MAIN MENU to return to the Main Menu.

Flow Control:
XON / XOFF

Every command and response is controlled by the CableSHARK using this software
flow control method (XON resumes transmission of data and XOFF pauses it). The
XON / XOFF flow control compensates for overflow errors that may exist at higher
baud rates or can exist if the user sends a command to the CableSHARK when the
CableSHARK is still processing information. In this instance, the XON / XOFF flow
control will indicate to the PC that the CableSHARK is busy.

Modem Init.
String:

To change the Modem Initialization String, use the Arrow Keys to move the cursor so
that the current Modem Initialization String is highlighted. Use the Alphanumeric
Keypad to enter the desired string. The Modem Initialization String follows the industry
standard Hayes Modem command Set. Press ENTER when the value is correctly
entered to save your changes. More parameters can be changed at this point, or
press MAIN MENU to return to the Main Menu.

Set Factory
Default:

Allows the user to force a COLD START REBOOT of the unit to clear NVRAM and
invoke the factory default settings. Setting SET FACTORY DEFAULT to YES will reset
the unit, clear the NVRAM, and invoke the factory default settings.

NOTE: THIS FUNCTION WILL ERASE ALL SAVED RESULTS THAT ARE STORED
IN THE CABLESHARK’s NVRAM.

There is no effect on results saved to USB Memory.