beautypg.com

EXFO CableSHARK P3 VF/DSL Cable Qualifier User Manual

Page 143

background image

CableSHARK P3 User Guide

131

ENTER

Test Type :

Cable Type:

E

F

CHG

AUTOTEST-12 (V,R,C)

WARNING

Please ensure that the test set is connected in parallel with

the load. Other connections may result in inaccurate readings.
Note: telephone cable may have dangerous A.C. or D.C.
Voltages on them, therefore caution should be taken when

connecting this test set.

!

Use arrows to scroll and RUN key or ENTER button to select

AUTO

Test Type :

AUTOTEST-14
AUTOTEST-12
VOLTAGE

SHORTS METER
OPENS METER
CURRENT

(V,R,C,I)
(V,R,C)
(V)

(R)
(C)
(I)

AUTOTEST-12 (V,R,C)

F

IGURE

8.7.1A

DMM

S

ETUP

M

ENU

The DMM Test Setup menu has several options that appear at the upper part of the screen (see the
previous illustration). The parameters can be modified to customize a DMM Test. The DMM Test setup
options are described as follows:


TEST TYPE:

Select from Autotest-14, Autotest-12, Voltage, Resistance, Capacitance or
Current

. Please following the warning screens on the CableSHARK for best use

practices. Use common sense when connecting the CableSHARK to the line.
Telecommunication lines can carry hazardous voltages.

The Autotest selections allow the user to do an automatic DMM test. The unit will
test, in order, Voltage, Resistance and Capacitance. The Autotest-14 will also do
a Current test.

NOTE: If Measurement Standards under System Setup is set to ANSI, then
the CableSHARK’s RESISTANCE Measurement will be titled SHORTS
METER and the CAPACITANCE Measurement will be titled OPENS METER.