Good bad ok – EXFO CableSHARK P3 VF/DSL Cable Qualifier User Manual
Page 134

VF / DSL Cable Qualifier
122
Longitudinal Balance test complete. Complies with ANSI T1.413 and G.DMT.
MAIN
MENU
E
F
CHG
SAVE/
UPLOAD
dB
26
571
1117
2208 kHz
1662
Balance
Cursor position
= 60.2 dB
= 564.938 kHz
0.0
20.0
40.0
60.0
80.0
SHOW
REF
Impedance = 100 ohms
ZOOM IN
HORIZ
ZOOM IN
VERT
TEST
SETUP
Press or to move cursor
dB
0.0
20.0
40.0
60.0
80.0
Good
Bad
Ok
F
IGURE
8.5.2B
–
G
OOD VS
B
AD RESULT
At the completion of a test, the Function button command selection at the bottom of the LONGITUDINAL
BALANCE TEST RESULT screen consists of six options available to the operator. The following are brief
descriptions of each of the Function button options:
SHOW REF
Pressing the function button corresponding to SHOW REF allows a user to
overlay a REFERENCE MASK over the test result on screen to compare the
two. See Section 5.4 for more information about the REFERENCE MASK
feature.
Pressing the SAVE / UPLOAD button shows a pop-up window where the user is allowed to upload results,
and save results to internal memory or to external USB memory.
UPLOAD RESULT
Choosing UPLOAD RESULT from the SAVE / UPLOAD pop-up menu sends
the result that appears on the CableSHARK screen (current test or recalled
test) to a PC via a NULL modem cable. The remote control program Visi-
SHARK can be used to capture and analyze the results on a PC.
SAVE
TO
MEM
Choosing SAVE TO MEM from the SAVE / UPLOAD pop-up menu invokes
the SAVE SESSION menu. From here, the test results can be saved to
internal non-volatile memory. See Section 5.3 for more information.