VF / DSL Cable Qualifier

122

Longitudinal Balance test complete. Complies with ANSI T1.413 and G.DMT.

MAIN
MENU

E

F

CHG

SAVE/
UPLOAD

dB

26

571

1117

2208 kHz

1662

Balance
Cursor position

= 60.2 dB
= 564.938 kHz

0.0

20.0

40.0

60.0

80.0

SHOW
REF

Impedance = 100 ohms

ZOOM IN
HORIZ

ZOOM IN
VERT

TEST
SETUP

Press or to move cursor

dB

0.0

20.0

40.0

60.0

80.0

Good

Bad

Ok

F

IGURE

8.5.2B

G

OOD VS

B

AD RESULT

At the completion of a test, the Function button command selection at the bottom of the LONGITUDINAL
BALANCE TEST RESULT screen consists of six options available to the operator. The following are brief
descriptions of each of the Function button options:

SHOW REF

Pressing the function button corresponding to SHOW REF allows a user to
overlay a REFERENCE MASK over the test result on screen to compare the
two. See Section 5.4 for more information about the REFERENCE MASK
feature.


Pressing the SAVE / UPLOAD button shows a pop-up window where the user is allowed to upload results,
and save results to internal memory or to external USB memory.

UPLOAD RESULT

Choosing UPLOAD RESULT from the SAVE / UPLOAD pop-up menu sends
the result that appears on the CableSHARK screen (current test or recalled
test) to a PC via a NULL modem cable. The remote control program Visi-
SHARK can be used to capture and analyze the results on a PC.

SAVE

TO

MEM

Choosing SAVE TO MEM from the SAVE / UPLOAD pop-up menu invokes
the SAVE SESSION menu. From here, the test results can be saved to
internal non-volatile memory. See Section 5.3 for more information.