Longitudinal balance test, Dmm (digital multimeter) – EXFO CableSHARK P3 VF/DSL Cable Qualifier User Manual
Page 279

CableSHARK P3 User Guide
267
Longitudinal Balance Test
Single-end
test:
Near-End test plot with cursor & zoom
Frequency accuracy:
±
50 ppm
Accuracy:
±
2 dB
Vertical scale:
0 to 80.0 dB
Horizontal scale:
26 kHz to 2.2 MHz
DMM (Digital Multimeter)
For use on normal telephone network and broadband circuits
Mode:
DMM-12 autotest, DMM-14 autotest or individual measurements
DC voltage:
Range: 0 to 400 V auto-ranging
Resolution: 3 significant digits
Accuracy: ±1% of reading ±1 LSD
AC voltage
Range: 0 to 250 Vrms auto-ranging
Resolution: 3 significant digits
Accuracy: ±1% of reading ±1 LSD
Resistance:
Range:
0 to 999 M
Ω auto-ranging (30 MΩ for auto-test)
Resolution:
3 significant digits
Accuracy:
0 - 999
Ω, ±1% or ±5 Ω
1 k
Ω - 99 MΩ, ±1% of reading ±1 LSD
100 M
Ω to 999 MΩ, ±5% of reading ±1 LSD
Distance:
Up to 100,000 ft (30,000 m)
Capacitance:
Range:
200 pF to 10
μF auto ranging, auto zeroing
Resolution:
3 significant digits
Accuracy:
±2% of reading ±1 LSD
Distance:
Up to 100,000 ft (30,000 m)
Current:
DC Current: 0 to 110 mA