CableSHARK P3 User Guide

149






Wire Gauge Vs. V.O.P.

Here are some examples of typical VOP values for various telephone cables, given for insulation type and
wire gauge / size. :

Pulp

AWG 22 0.6 mm VOP = 0.68 (102 m/

μs)

AWG 24 0.5 mm VOP = 0.67 (100 m/

μs)

AWG 26 0.4 mm VOP = 0.66 (99 m/

μs)


PIC

AWG 19 0.9 mm VOP = 0.72 (108 m/

μs)

AWG 22 0.6 mm VOP = 0.67 (100 m/

μs)

AWG 24 0.5 mm VOP = 0.66 (99 m/

μs)

AWG 26 0.4 mm VOP = 0.64 (96 m/

μs)


Jelly

AWG 19 0.9 mm VOP = 0.68 (102 m/

μs)


Filled

AWG 22 0.6 mm VOP = 0.62 (93 m/

μs)

AWG 24 0.5 mm VOP = 0.60 (90 m/

μs)

AWG 26 0.4 mm VOP = 0.58 (87 m/

μs)


Polyethylene

VOP = 0.66 (99 m/

μs)

Polypropylene

VOP = 0.66 (99 m/

μs)

Teflon

VOP = 0.67 (100 m/

μs)


8.10.2 LoopMapper Testing

With the appropriate VOP and horizontal units selected, the CableSHARK should be able to automatically
locate any cable reflection. Results will be displayed in feet or meters. Figure 8.10.2A shows a sample
LoopMapper test screen.