Link
The status of the link between the port and the end node connected to
the port. Possible values are:
Up - indicates that a valid link exists between the port and the end
node.
Down - indicates that the port and the end node have not established a
valid link.
Neg
The status of Auto-Negotiation on the port. Possible values are:
Auto - Indicates that the port is using Auto-Negotiation to set operating
speed and duplex mode.
Manual - Indicates that the operating speed and duplex mode were set
manually.
MDI/X
The operating configuration of the port. Possible values are MDI and
MDI-X.
Speed
The operating speed of the port. Possible values are:
0010 - 10 Mbps
0100 - 100 Mbps
1000 - 1000 Mbps (Optional expansion ports only.)
Duplex
The duplex mode of the port. Possible values are half-duplex and full-
duplex.
PVID
The port VLAN identifier assigned to the port.
Flow Control
The port’s flow control setting. Possible values are:
Enabled - Flow control is enabled on the port.
Disabled - Flow control is disabled on the port.
STP State
The operating status of the port. Possible values are Forwarding,
Blocking, Listening, and Learning.
HOL Limit
The utilization threshold of a port’s egress queue which initiates the
Head of Line Blocking prevention mechanism. The number for this
value represents cells. A cell is 64 bytes. The range is 1 to 61,440