Modifying the event log full action, Figure 31: modifying event log output 1 window – Allied Telesis AT-S62 User Manual
Page 127

AT-S62 Management Software Web Browser Interface User’s Guide
Section II: Advanced Operations
127
The columns in the log are described below:
S (Severity) - The event’s severity. Table 2 on page 124 defines the
different severity levels.
Date/Time - The date and time the event occurred.
Event ID - A unique number that identifies the event. (Displayed only in
the Full display mode.)
Filename:Line - The subpart of the AT-S62 module and the line
number that generated the event. (Displayed only in the Full display
mode.)
Event - The module within the AT-S62 software that generated the
event followed by a brief description of the event. For a list of the
AT-S62 modules, see Table 3 on page 125.
Modifying the
Event Log Full
Action
This procedure explains how to control what the log will do once it reaches
its maximum capacity of 4,000 events. You have two options. The first is to
have the switch delete the oldest entries as it adds new entries to the log.
The second is to have the switch stop adding entries, so as to preserve the
existing log contents.
This procedure is only relevant when viewing the event log through a local
or remote management session. If you defined syslog servers, the switch
continues to send events to a syslog server even when the log is full.
To configure the event log, do the following procedure:
1. From the Home Page, click either Configuration.
2. Select the System menu option.
3. Select the Event Log tab.
The Event Log tab is shown in Figure 29 on page 123.
4. Under Current Log Outputs, select Output 1, Temporary, and click
Modify. The Modifying Event Log Output 1 window is shown in Figure
31.
Figure 31. Modifying Event Log Output 1 Window