beautypg.com

Allied Telesis AT-S62 User Manual

Page 133

background image

AT-S62 Management Software Web Browser Interface User’s Guide

Section II: Advanced Operations

133

ˆ

LOCAL6

ˆ

LOCAL7

Each setting represents a predefined RFC 3164 numerical code. The
code mappings are listed in Table 5.

For example, selecting LOCAL2 as the facility level assigns the
numerical code of 18 to all events sent to the syslog server by the
switch.

Module Selections
The originating module of the events to be sent to the syslog server.
The AT-S62 management software consists of a number of modules,
each responsible for a different part of switch operation. You can use
this parameter to instruct the switch to send only those events that
originated from selected modules. The default is ALL, which sends the
events from all modules. The modules are defined in Table 3 on
page 125. T
o select more than one module, hold down the Ctrl key
when making your selections.

6. After configuring the syslog server definition, click Apply.

The switch adds the new syslog server definition to the Event Log tab
and immediately begins sending events to the server if you enabled
the Message Generation option.

7. To permanently save the change, click the Save Config menu

selection.

Table 5. Numerical Code and Facility Level Mappings

Numerical

Code

Facility Level Setting

17

LOCAL1

18

LOCAL2

19

LOCAL3

20

LOCAL4

21

LOCAL5

22

LOCAL6

23

LOCAL7