AT-S62 Management Software Web Browser Interface User’s Guide
Section III: SNMPv3
223
6. In the Group Name field, enter a descriptive name of the group.
The Group Name can consist of up to 32 alphanumeric characters.
You are not required to enter a unique value here because the
SNMPv3 Access Table entry is indexed with the Group Name, Security
Model, and Security Level parameter values. However, a unique group
name makes it easier for you to tell the groups apart.
There are four default values for this field that are reserved for
SNMPv1 and SNMPv2c implementations:
defaultV1GroupReadOnly
defaultV1GroupReadWrite
defaultV2cGroupReadOnly
defaultV2cGroupReadWrite
Note
The Context Prefix field is a read only field. The Context Prefix field
is always set to null.
7. In the Read View Name field, enter a value that you configured with
the View Name parameter in the SNMPv3 View Table.
This parameter allows the users assigned to this Group Name to view
the information specified by the View Table entry. This value does not
need to be unique.
8. In the Write View Name field, enter a value that you configured with the
View Name parameter in the SNMPv3 View Table.
This parameter allows the users assigned to this Security Group to
write, or modify, the information in the specified View Table. This value
does not need to be unique.
9. In the Notify View Name field, enter a value that you configured with
the View Name parameter in the SNMPv3 View Table.
This parameter allows the users assigned to this Group Name to send
traps permitted in the specified View. This value does not need to be
unique.
10. In the Security Model field, enter an SNMP protocol.
Select one of the following SNMP protocols as the Security Model for
this Group Name.