beautypg.com

Allied Telesis AT-S62 User Manual

Page 41

background image

AT-S62 Management Software Web Browser Interface User’s Guide

Section I: Basic Operations

41

BOOTP or DHCP, refer to “Activating the BOOTP or DHCP Client
Software” on page 38.

ˆ

Application Software and Build Date - The version number and

build date of the AT-S62 management software.

ˆ

Bootloader and Build Date - The version number and build date of

the AT-S62 bootloader.

ˆ

Main Power Supply - The status of the switch’s internal power

supply.

ˆ

Redundant Power Supply - The presence of a connection between

the switch and an RPS unit. The status will be “Not Connected” if
the switch is not connected to an RPS unit. If the switch is
connected to an RPS unit, the status will be “On,” even if the RPS
module itself is powered off.

ˆ

System Power - The status of the power voltages from the power

supply.

ˆ

System Temperature - The ambient air temperature as measured

where the air enters the cooling vents on the side of the switch.

ˆ

System Fan Speed - The speed of the cooling fans. The number of

fans vary by model. The AT-8516F/MT, AT-8516F/SC, and
AT-8524M switches have one fan, the AT-8524POE switch has five
fans, and the AT-8550GB and AT-8550SP switches have two fans.