Ip address reference 307 – Lab.gruppen PLM 20K44 User Manual
Page 312

Lake Controller Operation Manual Rev 1.5.4
IP Address Reference
307
▸
Dante specific documentation included in the Lake Controller software installation
▸
Lake Processing forum @
If desired, you can also use Class A (except for PLM+), Class B (recommended) or Class C private IP ad-
dress ranges. These addresses require additional configuration, and thus more knowledge of IP addresses
and networking. Table 28-1 shows a selection of private IP address ranges recommended for use with the
Lake device and Lake Controller network. It is recommended that all hardware is configured with a private IP
address within these ranges.
Class
Range
A
10.x.x.x
B
169.254.x.x (Default - Automatic Private IP Address) - RECOMMENDED
C
172.16.x.x through 172.31.x.x*
D
192.168.0.x through 192.168.255.x
Table 28-1: Recommended Private IP Addresses
*172.31.x.x is used on the secondary computer’s network
interface for Dante Dual Redundancy configuration. Please
refer to chapter 3 for further details.
Lake devices and Lake Controllers can be configured to communicate over a network using any IP address
and subnet mask combination required for your particular application. More sophisticated networks that
include traffic from other professional and consumer equipment must be configured correctly to achieve
desired operation.
IP Address & Dual Redundancy settings can only be
changed either manually by the user via software, or via a
Factory Reset. These parameters are unaffected by System
Recall, Preset Recall, Frame Replace, Soft Reset etc.