Lake Controller Operation Manual Rev 1.5.4
Firmware Update
293
An hourglass will display with the text “Dante version...”; if this
does not complete within 30 seconds, press the Refresh Dante
button. If the issue continues, open the Dante Controller and
press “Reload Device Information”, or restart the computer.
.
6. Tap SELECT OLD and then UPDATE. A warning message appears.
Figure 26-4: Firmware Update Warning Message
7. Tap OK in response to the warning message. All selected devices are updated in parallel with the latest
firmware. A green tick indicates the firmware is already at the latest version, a percentage indicates the
update status for the devices currently being updated, and a red cross indicates the firmware is old and
is awaiting update or the device requires a power-cycle to complete the upgrade.
Figure 26-5: Firmware Update Status
8. Wait for all devices to be updated.
A message appears, indicating that you must restart the updated Frames. When the firmware is updated,
the warning advises that the mains power must be cycled (using the standby button on the Front Panel is
not sufficient). For the MY8-LAKE, please power-cycle the host device.