274

Lake Controller Operation Manual Rev 1.5.4

LM Series Reference and Operation

Super Module View filters the results to show events that apply to all Modules in the Super Module.

Global View displays all results for all devices in the system configuration.

The data set for the most recent event is repeated in

the separate horizontal pane at the bottom of the

table.

21.3.7.1 Log Entries

Seven items of information per event are displayed in the log in tabular form, as follows:

EVENT – Displays system faults or warning notifications. Icons shown below reference the source of
the notification. Icons change color, from yellow (warning) to red (fault) to indicate severity.

START TIME – Displays the system time and date at which the event occurred

DURATION – Displays ACTIVE while the fault/warning is active. Once the fault/warning becomes
inactive, the duration for which it was active is displayed. Once the event is cleared, its line of text in
the log changes color from white to gray.

FRAME – Identifies the Frame in which the fault/warning/event occurred by displaying the Frame label.
If a Frame label has not been allocated, this field displays the default product model name i.e. LM 26.

MODULE – Displays the name of the Module in which the event occurred. This will be the default
name if the Module has not been renamed (i.e. CL3way, 2aux, etc.).

CHANNEL – Indicates the channel on which the event occurred. This column will be blank if the event
was a Frame event – e.g. network failure, etc.

DESCRIPTION – Displays a description of the event. A full list of the possible warning messages can be
found in the product Operation Manuals.

21.3.7.2 Sorting Options

The default listing order for the data displayed in the event log is chronological, with the most recent event
at the bottom of the list. To sort the data by another column, tap the button at the top of the required
column.