beautypg.com

Designer mode menu reference 227 – Lab.gruppen PLM 20K44 User Manual

Page 232

background image

Lake Controller Operation Manual Rev 1.5.4

Designer Mode Menu Reference

227

8. Tap EQ OVERLAY HIDE (illuminates orange), then tap OVLAY PROP EXIT.

When an EQ overlay is hidden, the effect its filters

have on the overall EQ curve are not visible in User

Mode or when the Module is locked.

To add GEQ and set the overlay to View Only, perform the following steps:

9. Tap EQ OVERLAY NEW. The overlay Group 1/PEQ2 is created.

10. Tap EQ OVERLAY GEQ, then YES to the warning message.

11. Reduce the 4 kHz filter by 4 dB.

12. Tap EQ OVERLAY PROPERTIES, then EQ OVERLAY VIEW ONLY (illuminates orange).

To verify the effect of the changes, perform the following steps:

13. Tap HOME, then USER PREFERENCES.

14. Tap DESIGNER MODE to return to User Mode (button becomes blue).

15. Tap HOME, then tap the GROUP 1 icon and navigate to EQ.

PEQ1 is hidden, and its filter is not displayed in the EQ curve, although its effect is still audible. GEQ2 is
displayed as View Only, and most functions are disabled.

19.2.3.2 Summary

Because a Group may contain various types of Modules with different security settings, Group security is
limited to EQ overlays only. Crossovers are not relevant to Groups, and all security for levels is controlled via
individual Modules.

19.2.4 Security for Global Access Functions

Global Access settings affect all Modules and Groups within a system configuration. To enable Global
Access mode, perform the following steps:

1. From HOME, tap USER PREFERENCES.

2. Tap DESIGNER FUNCTIONS. Ensure Designer Mode is active - orange.

3. Tap GLOBAL ACCESS.