Firmware update – Lab.gruppen PLM 20K44 User Manual
Page 297

292
Lake Controller Operation Manual Rev 1.5.4
Firmware Update
Figure 26-2: Network Adapter Selection
5. Select the wired adapter to which the Lake devices are connected.
The Lake devices will appear in a list with their current firmware versions displayed, similar to that shown in
Figure 26-3. The firmware version to be loaded is shown at the top of the screen (target firmware); this will
default to the latest version available.
Figure 26-3: Lake Update Utility Main Screen
For PLM+ and D Series, the firmware update utility must be able to read the Dante component before the
firmware update can start; ensure the network adapter selected for firmware update is on the same subnet
as Dante (169.254.x.x) and ensure the Lake Update Utility has full access through the firewall.