Communication and synchronization 199 – Lab.gruppen PLM 20K44 User Manual
Page 204
Lake Controller Operation Manual Rev 1.5.4
Communication and Synchronization
199
▸
A OUT-OF-SYNC Modules are set to VIEW ONLY pending synchronization.
▸
B The settings currently viewed are:
COMPUTER - Frame/Module name highlighted in red as offline
PROCESSOR - Frame/Module name displayed in blue text as online
▸
C The main part of the screen changes to show the Computer and Processor settings as selected.
▸
D The help text shown here indicates the type of data that is out of sync.
Navigate to the relevant section of the system to view/update.
▸
E The
OUT OF SYNC warning message is visible on all screens.
▸
F This button changes labels depending on the currently selected view.
SHOW PROCESSOR - when viewing computer settings
SHOW COMPUTER - when viewing device (Processor) settings
▸
G Tapping this button updates either the computer or the device with the settings being viewed.
To compare and update settings stored in the Lake Controller software and Lake devices, perform the
following steps:
1. From the HOME menu, tap a Module icon that is out of sync.
An out-of-sync Module is indicated by a red disc behind the normal Module icon.
2. View the help text [D] that advises which parameters are affected.
3. Navigate to the relevant EQ/LEVELS page. Computer settings are displayed by default.
4. Tap SHOW PROCESSOR/SHOW COMPUTER [F] to compare settings.
5. Decide which settings to use, and tap USE THESE SETTINGS.
6. Repeat the process for each out-of-sync Module.
Alternately, all Modules can be updated with the USE DATA IN COMPUTER or USE DATA ON PROCESSOR
functions.
16.3.6 Audible Changes when Synchronizing
If a Module becomes out of sync while audio is being processed, choosing to synchronize with the Control-
ler could affect the sound, depending on the values that are out of sync.
If the Controller EQ/XOVER/LEVELS settings differ from those currently used by the device, the audio
signal may change or be momentarily muted while settings are configured if USE DATA IN COMPUTER is
selected.