Lm series reference and operation 275 – Lab.gruppen PLM 20K44 User Manual
Page 280

Lake Controller Operation Manual Rev 1.5.4
LM Series Reference and Operation
275
21.3.7.3 Filtering Options
The default event log records and displays all events for all Modules on all Frames on the system. It is pos-
sible to reduce the number of log entries displayed by applying filter options available on the right hand side
of the table. Regardless of filtering options currently selected, all events are recorded, and may be displayed
later as required.
Severity
Recorded events are divided into three categories: FAULTS, WARNINGS and USER ACTIONS. Events in any
or all of these categories may be displayed in the log by tapping the three buttons in the SEVERITY box. The
ALL button restores the default state of all three categories being selected.
Source
Using buttons in the SOURCE box, events may also be filtered on the basis of which part of the system
generated them. Some of these sources apply only to Lake-enabled amplifiers and will only be relevant for
mixed system configurations. Any or all of the event sources may be selected; the sources relevant to LM
Series devices include:
▸
Frame > Device
▸
Other > Audio Distribution
▸
Other > Network
The ALL button restores the default state of all six categories being selected.
Time
It is possible to display only events which have occurred within a user-defined time interval, using the
buttons in the TIME box. The options are:
▸
SINCE HH:MM – Tapping the HH and MM buttons opens a numeric keypad to allow a ‘Start time’ for
displayed events to be entered. Tapping the Since button activates the option.
▸
LAST POWER CYCLE – Tapping this button causes the Event Log to only display events which have
occurred since the last time the device was powered up.
21.3.8 Event Log Files
When a session ends, the session’s EVENT LOG is written to a file.