Lake-enabled amplifier reference – Lab.gruppen PLM 20K44 User Manual
Page 263

258
Lake Controller Operation Manual Rev 1.5.4
Lake-enabled Amplifier Reference
Selecting Custom RPM mode disables Auto RPM mode; please refer to the CAFÉ Operations Manual for
further information on setting Custom RPM settings.
When RPM is active, RPM text is displayed next to the Actual ISVPL values.
20.10.4 ISVPL Profile
The ISVPL profile controls attack and release times of the ISVPL limiter along with the associated voltage
clip behavior. There are six options available as shown and described in Figure 20-11.
Figure 20-11: ISVPL Profile Options
20.10.5 Amplifier Clip Level
The Amplifier Clip level is calculated from Amplifier Gain and ISVPL Speaker Threshold values. This figure
represents the digital signal level from the Module output that will produce clipping or limiting at the power
output channel. If no EQ or additional gain is applied in the Lake Processing Module, this figure also repre-
sents the digital input level at which clipping or limiting will be produced at the power output channel.
The ALL column parameter displays if all values for
the parameter type are identical.